5.3 Servomotor Rotation Direction

E-45

English

5.3 Servomotor Rotation Direction

The servomotor rotation direction can be reversed with parameter Pn000.0 without changing the polarity of the
position reference.

The standard setting for forward rotation is counterclockwise (CCW) as viewed from the load end of the servomotor.

Parameter

Forward/

Reverse

Reference

Direction of Motor Rotation

Pn000

n.†††0
The forward rotation is CCW.
[Factory setting]

Forward
Reference

Reverse
Reference

n.†††1
The forward rotation is CW.
(reverse rotation mode)

Forward
Reference

Reverse
Reference

Forward

(CCW)

Reverse

(CW)

Reverse

(CW)

Forward

(CCW)