3.1 Precautions on Wiring
E-20
Molded-Case Circuit Breaker (MCCB) or Fuse Capacity Relation to Power-Supply Capacity
* 1. Valued obtained with the servomotor with the rated output.
* 2. Fuse manufactured by Littelfuse Inc.
Ground Fault
The ground protection circuit is designed for ground fault inside the motor windings while the motor
is running. Therefore, it may not protect the system under the following conditions.
• A low-resistance ground fault occurs between the main circuit cable and connector for the ser-
vomotor.
• The power supply is turned ON during a ground fault.
To configure a safer system, install an earth leakage breaker for protection against overloads and
short-circuiting, or install an earth leakage breaker combined with a wiring circuit breaker for ground
protection.
MCCB or Fuse Capacity Relation to Power-Supply Capacity
Main
Circuit
Power
Supply
SERVOPACK
Applicable Ser-
vomotor
Model:
SJME-
Power-
Supply
Capacity
kVA
MCCB
Current
Capacity
Arms
∗1
External Fuse
Model No.
[Power-Supply
Capacity
Arms]
∗2
Inrush
Current
A
Capacity
kW
Model No.:
SJDE-
Single-
phase
200 V
0.1 01APA-OY
01AM41
0.4
4
0KLK 015.T
[15]
30
01AM41-OY
0.2 02APA-OY
02AM41
0.75
02AM41-OY
0.4 04APA-OY
04AM41
1.2
8
04AM41-OY
0.75 08APA-OY
08AM41
2.2
16
0KLK 030.T
[30]
60
08AM41-OY
NOTE