2.1 Installation Conditions

E-16

2 Installation

The following shows the installation location and method of the SERVOPACK.

2.1 Installation Conditions

Item

Specifications

Operating temperature

0

°C to +55 °C

Operating humidity

90% RH or less (with no condensation)

Storage temperature

-20

°C to +70 °C

Storage humidity

90% RH or less (with no condensation)

Installation site

Free of corrosive gases
Free of dust and iron powder
Clean and dry

Altitude

1000 m or below

Vibration resistance

4.9 m/s

2

Shock resistance

19.6 m/s

2

Operating conditions

Installation category (overvoltage category): II
Pollution degree: 2
Protection class: IP10 (EN50178)

Installation
Site

Installation in a control
panel

Design the control panel size, unit layout, and cooling method so
the temperature around the SERVOPACK does not exceed 55

°C.

Note: For long-term reliability the internal temperature of the control

panel must be 45

°C or lower.

Installation near a
heating unit

Minimize the heat radiating from the heating unit as well as any
temperature rise caused by natural convection so the temperature
around the SERVOPACK does not exceed 55

°C.

Installation near a
source of vibration

Install a vibration isolator beneath the SERVOPACK to avoid subjecting
it to vibration.

Installation at a site
exposed to corrosive
gas

Corrosive gas does not have an immediate effect on the SERVOPACK
but will eventually cause the electronic components and contactor-
related devices to malfunction. Take appropriate action to avoid corro-
sive gas.