3.5 SERVOPACKs and Applicable Peripheral Devices
E-28
3.5 SERVOPACKs and Applicable Peripheral Devices
* 1. Nominal value at the rated load. The specified derating is required to select the appropriate molded-case circuit breaker.
* 2. Cut-off characteristics (25
°C): 200 % two seconds min. and 700 % 0.01 seconds min.
Note: 1. The ground protection circuit is designed for ground fault inside the motor windings while the motor is running.
Therefore, it may not protect the system under the following conditions.
• A low-resistance ground fault occurs between the main circuit cable and connector for the servomotor.
• The power supply is turned ON during a ground fault.
To configure a safer system, install an earth leakage breaker for protection against overloads and short-circuiting,
or install an earth leakage breaker combined with a wiring circuit breaker for ground protection.
2. It is recommended to use a general-purpose circuit breaker of the rated current 200 mA or more, or a circuit
breaker for inverters (for high-frequency).
3.6 Main Circuit Wiring
• SJDE SERVOPACKs are suitable where the power supply is less than 5000 Arms (230 V max.).
• SERVOPACKs must be used with UL-listed fuses or circuit breakers, in accordance with the National Electrical
Code (NEC).
• Use 75
°C heat-resistant copper wires or an equivalent.
3.7 SERVOPACK Main Circuit Wire Size
Cable Types
• Wire sizes are selected for three cables per bundle at 40
°C ambient temperature with the rated current.
• Use cables with a minimum withstand voltage of 600 V for main circuits.
• If cables are bundled in PVC or metal ducts, consider the reduction ratio of the allowable current.
• Use heat-resistant cables under high ambient or panel temperatures where normal vinyl cables will rapidly deteri-
orate.
• Do not use cables under continuous regenerative state.
SERVOPACK
Power
Supply
Capacity per
SERVOPACK
kVA
Current
Capacity of
Molded-case
Circuit Breaker
Arms
*1 *2
Current
Capacity and
Model of
External
Fuse
Inrush
Cur-
rent
A0-p
Magnetic
Contac-
tor
*3
Noise
Filter
Surge
Absorber
AC
Reactor
Type
Capa-
city
SJDE-
01APA-OY
100 W
0.40
4
0KLK
015.T
(15 Arms)
30
HI-11J
FN2070
-6/07
R
x
C
x
M-
601BQZ-4
X5052
SJDE-
02APA-OY
200 W
0.75
X5053
SJDE-
04APA-OY
400 W
1.2
8
FN2070
-10/07
X5054
SJDE-
08APA-OY
750 W
2.2
16
0KLK
030.T
(30 Arms)
60
HI-15J
FN2070
-16/07
X5056
Manufacturer
−
−
Littelfuse
Inc.
−
Yaskawa
Controls
Co., Ltd.
Schaffner
Electronic
Okaya
Electric
Industries
Co., Ltd.
(Sold as:
Surge
Protector)
Yaskawa
Controls
Co., Ltd.
Symbol
Name
Allowable Conductor Temperature
PVC
Normal vinyl cable
−
IV
600 V vinyl cable
60
°C
HIV
Temperature-resistant vinyl cable
75
°C