beautypg.com

Yaskawa VS-616PS5 Series Programming Manual User Manual

Page 74

background image

74

VS-616PS5 Programming Manual

H3

Analog Inputs
The VS-616PS5 has three analog inputs (two multi-function and one fixed), for the
external input of numerous references and limits, including speed, torque, PID, and
others. This section includes descriptions of these functions.

Selects the type of voltage signal input at terminal 13.

The resolution of terminal 13 is 11 bit, plus a sign bit.

Setting Range:

0.0 to 1000.0%

Factory Default:

100.0%

Sets the terminal 13 input gain level when the reference voltage is 10V.

Setting Range:

±

100.0%

Factory Default:

0.0%

Sets the terminal 13 input bias level when the reference voltage is 0V.

Selects the type of voltage signal input at terminal 16.

The resolution of terminal 16 is 11 bit, plus a sign bit.

H3-01 Terminal 13 Signal Selection

B

Setting

Description

0

0 to 10V input (factory default)

1

-10 to +10V input

H3-02 Terminal 13 Reference % Gain

B

H3-03 Terminal 13 Reference ±% Bias

B

H3-04 Terminal 16 Signal Selection

A

Setting

Description

0

0 to 10V input (factory default)

1

- 10 to + 10V

input

Figure 46 Analog Input Gain and Bias Adjustment

H3-

02=

100

%

H3-02=

50%

0

4

10V

20mA

(Bias)

H3-02

(Gain)

% Reference

H3-02

Section H: Control Circuit Terminal Parameters

H3 Analog Inputs