beautypg.com

Yaskawa VS-616PS5 Series Programming Manual User Manual

Page 44

background image

44

VS-616PS5 Programming Manual

E

Motor Parameters

E1

Motor Constant

Setting Range:

180 to 230V (360 to 460V)

Factory Default:

230V (460V)

Set E1-01 to the nominal expected line voltage (exact setting is not required)
This setting adjusts the overvoltage level, the braking transistor turn on level, and the
stall prevention level during deceleration.

Only built-in type braking transistors will be affected, not CDBR units.

Setting Range:

1000 to 1239

Factory Default:

0

Used in conjunction with the motor connection selection (E1-17) to automatically load
the motor parameter (E1-03 thru E1-13) from a pre-programmed look-up table. When
setting E1-02 to any setting other than 1000, be sure to set E1-17 to the proper con-
nection setting first. Then, set E1-03 to the proper motor winding type. When set to
1000, manual entry of parameter E1-03 - E1-13 is required.
Do not change the value after it has been set as the motor parameters will be modi-
fied.

Setting Range:

0.0 to 255.0V (0-510.0 V)

Factory Default:

230.0 (460.0)

Sets the motor rated voltage. Set to 230.0 for 320VDC nameplated motors and 460.0
for 640VDC nameplated motors.

E1-01 Inverter Input Voltage Setting

Q

Inverter

Voltage

E1-01

Setting

Overvoltage Trip

Braking Transistor

Stall

Level

Trip

Reset

ON

OFF

230

150 - 255

400V

380V

380V

375V

380V

460

>400

800V

760V

760V

750V

760V

460

<400

720V

680V

660V

650V

670V

E1-02 Motor Capacity Selection

Q

E1-03 Motor Rated Voltage

Q

Section E: Motor Parameters

E1 V/f Pattern