F8

PG Option Set-up 2

Setting Range:

0,1

Factory Default:

1

Selects the speed feedback method (hall sensor or line drive encoder).

Setting Range:

0 - 50

Factory Default:

0

Sets the number of scans the Pulse Train reference is averaged. A larger number will
provide a more stable speed reference signal, however, the inverter response to a
rapid change in reference may be slower.
A setting of “0” or “1” means no moving average will be used, and the pulse train ref-
erence will be updated every scan.

F8-01 Speed Feedback Detection Method

Q

Setting

Description

0

Speed feedback comes from channels A & B on PG-P2 option

1

Speed feedback comes from channels HS4 & HS5 input on PG-P2 option

F8-01 Pulse Train Average Value

B

Section F: Option Parameters