46

VS-616PS5 Programming Manual

Setting Range:

0 to 65.535

Factory Default:

0.000 (E1-02=1000)

Set the terminal to terminal resistance of the motor in units of 0.001

Ω.

Setting Range:

0.00 to 6

00.00

mH

Factory Default: 0.00 (E1-02=1000)

The d Axis inductance is set in units of 0.01mH.

Setting Range:

0.00 to 6

00.00

m

Η

Factory Default:

0.00 (E1-02=1000)

This parameter sets the q Axis inductance in units of 0.01mH at the time the motor-
rated load is established. Set this value equal to the setting in parameter E1-10 for
surface magnet PM motors.

Setting Range:

20.0 to 500.0 V/1000 RPM

Factory Default:

0.0 (E1-02=1000)

This parameter sets the induced voltage RMS value for the motor in units of 0.1V/
1000 RPM. Enter the induced voltage generated at 1000 RPM motor speed. Make
sure the induced voltage at the maximum speed (E1-06 does not exceed the voltage
rating of the inverter.
Do not change the value after it has been set.

Setting Range:

0.0 to 10.0%

Factory Default:

0.0

The motor’s mechanical loss is set in units of 0.1%. Used to improve torque linearity
The motor’s rated output is 100%.

E1-09 Motor Terminal to Terminal Resistance

Q

E1-10 Motor d Axis Inductance

Q

E1-11 Motor q Axis Inductance

Q

E1-13 Induced Voltage Constant

Q

E1-15 Motor Mechanical Loss

A

Section E: Motor Parameters

E1 V/f Pattern