10  Maintenance and Cleaning

SMA Solar Technology AG

70

STP8-17TL-IA-en-31

Installation Manual

9. After cleaning, reassemble everything in reverse order.

10. Check that the fan is functional (see Section 10.2.4 "Checking the Fans", page 71).

10.2.3 Cleaning the Fan on the Left-hand Side of the Inverter

Enclosure

1. Disconnect the inverter (see Section 9 "Disconnecting the Inverter from Voltage Sources",

page 63).

2. Turn the rotary fastener of the ventilation grid in the

direction of the arrow until the notch is in a vertical
position.

3. Remove the ventilation grid.

4. Wait for the fan to stop rotating.
5. Press the latches in towards the centre.

6. Remove the fan by pulling it slowly and carefully

out sideways.

Damage to the fan through use of compressed air

• Do not use compressed air to clean the fan. This could damage it.