6  Electrical Connection

SMA Solar Technology AG

50

STP8-17TL-IA-en-31

Installation Manual

If the inverter is not set to the country of installation, there are several ways of configuring the required
country standard:

• Setting via the two rotary switches (see Section 6.5.3 "Setting the Country Standard and

Language using the Rotary Switch", page 52).

• Alternatively, you can carry out the settings via the "CntrySet" or "Set country standard"

parameters using a communication product, once you have commissioned the inverter.

• If you require adjusted parameter settings for your installation site, you can change these with

the help of a communication product.

D

5

Off-Grid60

not assigned*

no

flexible

D

6

Off-Grid60

not assigned*

no

flexible

E

0

Off-Grid50

English

no

flexible

E

1

Off-Grid50

German

no

flexible

E

2

Off-Grid50

French

no

flexible

E

3

Off-Grid50

Spanish

no

flexible

E

4

Off-Grid50

Italian

no

flexible

E

5

Off-Grid50

not assigned*

no

flexible

E

6

Off-Grid50

not assigned*

no

flexible

F

0

SD-Card

SD-Card

no

flexible

a)

Configurable from Firmware Version 2.31. Setting in accordance with VDE-ARN-4105
(Germany) for PV plants < 3.68 kVA

b)

Configurable from Firmware Version 2.31. Setting in accordance with VDE-ARN-4105
(Germany) for PV plants > 3.68 kVA and < 13.8 kVA

c)

Configurable from Firmware Version 2.31. Setting in accordance with VDE-ARN-4105
(Germany) for PV plants > 13.8 kVA

d)

Special setting: Bluetooth transmission power reduced (in accordance with French standards)

e)

Configurable from Firmware Version 2.50. Setting according to CEI 0-21 for PV plants with external grid and plant
protection > 6 kVA (Italy)

*

Currently not assigned. The previously configured display language is maintained.

**

Planned

(A) (B) Country data set

Display language Grid Guard

protection

Country