Protective Devices
General Data
DC reverse polarity protection
Short-circuit diode, electronic string fuse
Protection against module reverse currents
Electronic string fuse
Input-side disconnection device
Electronic Solar Switch, SUNCLIX DC connector
DC overvoltage protection
Thermally monitored varistors
optional: surge arrester type II
AC short-circuit current capability
Current control
Grid monitoring
SMA Grid Guard 4
Maximum permissible fuse protection
50.0 A
Earth fault monitoring
Insulation monitoring R
iso
> 458.7 k Ω
All-pole sensitive residual-current monitoring unit
available
String-failure detection
available
Width x height x depth with
Electronic Solar Switch
665 mm x 690 mm x 265 mm
Weight
59 kg
Length x width x height of packaging
780 mm x 380 mm x 790 mm
Transport weight
65 kg
Climatic class as per IEC 60721-2-1
4K4H
Operating temperature range
− 25°C … +60°C
Maximum permissible value for relative humidity,
non-condensing
100%
Maximum operating altitude above MSL
3,000 m
Power loss in night operation
< 1 W
Topology
transformerless
Cooling concept
OptiCool: temperature-controlled fan
Fan connection
designed for safe disconnection in accordance
with DIN EN 50178:1998-04
Degree of protection according to IEC 60529
IP65
Protection class (according to IEC 62103)
I