6.4 Connecting the PV Array (DC)

6.4.1 Conditions for DC Connection

The inverter has two input areas "A" and "B", each with its own MPP tracker.

Up to 4 strings (Sunny Tripower 8000TL/10000TL/12000TL) or 5 strings (Sunny Tripower 15000TL/
17000TL) can be connected at input area A. One string can be connected at input area B.

• For input area A, the PV modules must meet the following requirements:

– same type
– same number of in-series-connected PV modules
– identical alignment
– identical tilt

• For the activation of the intelligent string failure detection, the PV modules at input A and B must

be identically aligned.

• The connecting cables of the PV modules must be equipped with connectors. The connectors

required for DC connection are included in the scope of delivery.