Degree of protection in accordance with
IEC 60529
IP20 (NEMA 1)
Electromagnetic compatibility as per EN 55022 Class A
Maximum altitude above MSL
3,000 m (9,842 ft)
* If the flow rate of the ambient air is constantly ≥0.5 m/s, the ambient temperature range in operation
increases to −25°C to +70°C (−13°F to +158°F).
** non-condensing
Communication
Inverter
Speedwire
Local area network (LAN)
Ethernet
Data interfaces
HTTP, FTP, Modbus TCP / UDP, SMTP, Sun-
ny Portal
Maximum Cable Length for Communication
Speedwire*
100 m (328 ft)
Ethernet*
100 m (328 ft)
* between two nodes when using installation cables
Maximum Number of Devices
SMA devices with Speedwire interface
For model "CLCON-S-10": 25
For model "CLCON-10": 75
Network Ports
Quantity (Speedwire)
2
Quantity (LAN)
2
Auto-MDIX (auto-crossing)
Yes
Data transfer standard
10BaseT or 100BaseTx
Data transfer rate*
up to 10 Mbit/s or up to 100 Mbit/s
* Autonegotiation
Digital Inputs
Quantity
8
Input voltage
24 V
DC
Maximum cable length
30 m (98 ft)
Digital Outputs
Quantity
3