5

Mounting

5.1

Requirements for Mounting

Requirements for the mounting location:

Product can cause radio interference in living areas
The product is a device of ITE class A (EN 55022) and can cause radio interference in living
areas.

• Take suitable measures for shielding radio waves when the Cluster Controller is used in the

vicinity of living areas.

☐ The mounting location must be indoors.
☐ The ambient conditions at the mounting location must be suitable for the operation of the

Cluster Controller (see Section 9, page 84).

☐ The mounting location must be protected against dust, moisture and corrosive substances.

Maximum permitted cable lengths:

☐ Observe the maximum cable length of 100 m (328 ft) between any two nodes in the

Speedwire network and in the local area network (LAN).

☐ When connecting a digital or analog signal source (e.g. remote terminal unit, ripple control

receiver), observe the maximum cable length of 30 m (98 ft) from the Cluster Controller to the
signal source.

☐ When connecting a temperature sensor using the four-conductor method, observe the

maximum cable length of 20 m (65 ft) from the Cluster Controller to the temperature sensor.

☐ When connecting a temperature sensor using the two-conductor connection technology,

observe the maximum cable length of 2.5 m (8 ft) from the Cluster Controller to the
temperature sensor.

Minimum clearances:

☐ The minimum clearances must be maintained to ensure adequate heat dissipation.

5 Mounting

SMA Solar Technology AG / SMA America, LLC

Installation Manual

25