beautypg.com

SMA CLUSTER CONTROLLER Installation User Manual

Page 74

background image

LED

Status

Cause and corrective measure

Data carrier status
(

)

off

The Cluster Controller is starting and no information is
yet available for data export or for the USB data car-
rier.
Corrective measures:

• Wait until the Cluster Controller has completed

the start process and is ready for operation.
Once the start process is complete, the power
LED (

) will glow green.

No USB data carrier was detected. It is possible that
no USB data carrier is connected or the USB data
carrier is not compatible.
Corrective measures:

• Ensure that a compatible USB data carrier is

connected (see Section 9, page 84).

glowing green

The USB data carrier is compatible. The free storage
capacity is above 10%.

glowing yellow

The USB data carrier connected to USB port 1 is
compatible but the free storage capacity is no more
than 10%.
Corrective measures:

• Delete files that are no longer required from the

USB data carrier.
or

• Replace the USB data carrier with a USB data

carrier that has sufficient free storage capacity.

Data carrier status
(

)

glowing red

The USB data carrier connected to USB port 1 is full
or write-protected.
Corrective measures:

• If the USB data carrier is full, replace the USB

data carrier.

• If the USB data carrier is write-protected,

remove the write protection or use a USB data
carrier without write protection.

flashing green or
yellow or red

Write or read accesses are currently being per-
formed on the USB data carrier.
Corrective measures:

• Only remove the USB data carrier once the

data carrier status LED is no longer flashing.

7 Troubleshooting

SMA Solar Technology AG / SMA America, LLC

Installation Manual

ClusterController-IA-en-14

74