2 network port leds, Network port leds – SMA CLUSTER CONTROLLER Installation User Manual
Page 75

7.1.2
Network Port LEDs
LED
Status
Cause and corrective measure
Link/Activity
(green)
Off
No network connection established.
The Cluster Controller is not connected to the voltage sup-
ply.
Corrective measures:
• Connect the Cluster Controller to the voltage supply
No network connection established.
The network cable is not correctly connected to the Clus-
ter Controller, the router or the network switch.
Corrective measures:
• Ensure that the network cables are connected
correctly (see Section 6.9, page 41).
No network connection established.
One or more network components, network cables or con-
nectors are defective or damaged.
Corrective measures:
• Replace the defective or damaged network
components, network cables or connectors.
flashing
Network connection established.
Data is being sent or received.
Speed (yellow)
Off
Network connection established.
The data transfer rate is up to 10 Mbit/s.
on
Network connection established.
The data transfer rate is up to 100 Mbit/s.
7 Troubleshooting
SMA Solar Technology AG / SMA America, LLC
Installation Manual
75
ClusterController-IA-en-14