Magnifying details
You can magnify details in all display modes in the Test Run mode and
a program run mode.
The graphic simulation or the program run, respectively, must first
have been stopped. A detail magnification is always effective in all
display modes.
Changing the detail magnification
The soft keys are listed in the table.
8
Interrupt the graphic simulation, if necessary.
8
Shift the soft-key row in the Test Run mode, or in a program run
mode, respectively, until the soft key for detail enlargement
appears.
8
Select the functions for section magnification.
8
Press the corresponding soft key to select the
workpiece surface (see table below).
8
To reduce or magnify the blank form, press and hold
the MINUS or PLUS soft key, respectively.
8
Restart the test run or program run by pressing the
START soft key (RESET + START returns the
workpiece blank to its original state).
Function
Soft keys
Select the left/right workpiece surface
Select the front/back workpiece surface
Select the top/bottom workpiece surface
Shift the sectional plane to reduce or
magnify the blank form
Select the isolated detail