Chapter 3 Service Procedures
c. Click
Modify Team
. A dialog box opens.
9. On the
Adapters
tab, do the following:
a. Select the top entry, which is
Intel® PRO/1000 MT Dual Port Server Adapter
(Type
I MB) or
Intel® PRO/1000 EB Network Connection with I/O Acceleration
(Type II
and Type III MB), and click
Set Primary
.
b. Select
Intel® PRO/1000 MT Dual Port Server Adapter #3
(Type I MB) or
Intel®
PRO/1000 MT Dual Port Server Adapter
(Type II and Type III MB) and click
Set
Secondary
.
10. Click
OK
and
OK
and to close dialog boxes.
11. Do not create a media team for the media (iSCSI) network. The two remaining
connections remain as independent ports and are used as follows:
• Media Connection #1, which is GigE port 2 on the K2 Media Client rear panel,
is the connection for the media (iSCSI) network on a non-redundant K2 Storage
System, or for the “A” media (iSCSI) network on a redundant K2 Storage
System.
• Media Connection #2, which is GigE port 4 on the K2 Media Client rear panel,
is not used on a non-redundant K2 Storage System. It is the connection for the
“B” media (iSCSI) network on a redundant K2 Storage System.
12. Restart the K2 Media Client.
Continue with the next procedure
Name team
The following procedure is intended for use on shared storage models only.
1. On the Windows desktop right-click
My Network Places
and select
Properties
. The
Network Connections window opens.