Raid drive indicators, Rear panel indicators, Chapter 1 product description – Grass Valley K2 Media Client Service Manual v.3.3 User Manual
Page 40
40
K2 Media Client Service Manual
June 25, 2009
Chapter 1 Product Description
RAID drive indicators
On a K2 Media Client with a SCSI backplane, each RAID drive has LEDs that
indicate status. You must remove the fan module to see these LEDs. The following
table explains the status conditions indicated by the different LED behaviors. If two
or more status conditions occur simultaneously, the LED displays the behavior for the
highest priority condition.
On a K2 Media Client without a SCSI backplane, refer to
Manager to identify a failed drive” on page 54
.
Rear panel indicators
The following indicators are visible from the rear panel view.
Solid Red
Global failure — The K2 Media Client system
software has detected a critical error or failure that
impacts record/play operations.
2
Solid Yellow
Warning — The K2 Media Client system software has
detected a problem that requires attention but does not
immediately impact record/play operations. For
example, a fan or power supply has failed but its
redundant partner is maintaining functionality.
3
Flashing Yellow pattern three time
a second.
Drive failure — An internal RAID drive has failed. If
RAID 1, the failure does not immediately impact
record/play operations. The redundant partner RAID
drive is maintaining functionality.
4
Flashing pattern alternating
Yellow/Green once a second.
Drive rebuild — If RAID 1, an internal RAID drive is
rebuilding.
5
Off
Normal — The K2 Media Client is healthy and
operating normally.
5
LED behavior
Status Condition
Priority
Flashing pattern alternating
Yellow/Green/Red/Off twice a
second
Identify — The RAID drive is being directed to
identify itself by Storage Utility or some other
application.
1
Both Red and Green LED off
Drive is not fully engaged in slot.
2
Red LED is ON solid. Green LED
is off.
Fault — The SCSI controller has marked the drive as
faulty.
3
Flashing pattern alternating
Yellow/Green once a second
Rebuild — The SCSI controller has marked the drive
as rebuilding.
4
Red LED is off. Green LED
displays pulsing patterns.
Normal drive activity — The RAID drive is healthy
and disk access is underway. (Both LEDs are off when
there is no disk activity.)
5
LED behavior
Status Condition
Priority