SMPTE 311M Hybrid Fiber:
Standard Internal Power Supply w/PowerWafer
............................................................................................ 240m (787 ft): 95W @ 12VDC*
Long Range: HDX w/PowerPlus
........................................................................2km (6562 ft.): 100W Cont./150W Peak*
Mechanical/Environmental
Dimensions (WxLxD)
Camera Unit.................................................................................................. 2.5" x 6.5" x 2.2"
Base Station.................................................................................................17.5" x 9" x 1.75"
Power Wafer .................................................................................................. 5" x 6.12" x 2.2"
PowerPlus LP (100W) ....................................................................................... 5" x 6" x 2.5"
PowerPlus HP (150W) ...................................................................................... 5" x 6" x 3.7"
HDX................................................................................................................... 13" x 3.5" x 8.5"
Weight
Camera Unit......................................................................................................................1.5 lb.
Base Station......................................................................................................................5.0 lb.
PowerWafer ......................................................................................................................1.5 lb.
PowerPlus......................................................................................... LP: 2.3 lb.......HP: 2.5 lb.
HDX................................................................................................................................... 10.5 lb.
Power Consumption
Camera unit ............................................................................................... 8 watts@10-18VDC
Base Station (Tac Fiber):
Power Consumption ......................................................................10 watts@10-18VDC
Power Connector.................................................................................................. 4-Pin XLR
Base Station (Hybrid Fiber):
Power Req ............................................................. 110-120/220-240 VAC, 50 to 60Hz
Power Consumption ............................................................. 250 watts max @120VAC
Temperature Range..................................................................................... -25° to +55°C
Humidity Range ................................................................... 0 to 95% RH, Noncondensing
* The maximum cable length varies due to optical loss that can depend on cable quality,
dirt/dust/contamination on connectors, and the number of cable connectors. When using
hybrid cable for camera power, the size of the hybrid cable, as well as the power draw of the