beautypg.com

The copperhead 3400 base station digital display, The copperhead 3400 base station, Digital display – Grass Valley 3400 CopperHead User Manual

Page 76

background image

70

Operating the Transceiver System

The CopperHead 3400 Base Station Digital Display

The CopperHead 3400 Base Station Digital Display

The Base Station digital display has three functions selected by the Display Mode selector
button (#14 on

Figure D-2

). These functions are indicated by the Display Mode LEDs (#12).

BASE RX – Base Station Optical Power or Signal Strength that is being generated at the

Base Station and sent to the Camera Unit. Displayed in units of –dBm.

CAM RX – Optical Power or Signal Strength being generated by the Camera Unit as

measured at the Base Station. Displayed in units of –dBm.

DIAG – One of four diagnostics modes available to the Base Station:

TEMP – displays operating temperature in degrees Centigrade of each circuit board

that reports temperature

POWR – displays power level from monitored circuit boards

REV – displays microcontroller firmware version from each circuit board with a

microcontroller

CAM – displays the error status reported by the Camera Unit

To select the different display modes, push the Display Mode selector. The transition from
one mode to another may take a moment, with the transition into the Diagnostic mode
taking slightly longer. The selector is cyclical rotating through each of the modes. Once in
the Diagnostic mode, a quick push of the selector button cycles through the various
diagnostic sub-modes described above.

The following table describes the expected readouts in each of the above Base Station
display modes. Following this sequence will allow you to understand what the various
readouts and four-character abbreviations mean for the system.

Display Mode

Typical
Readout

Base Station Digital Display Activity Explanation

(assumes after initial power up – see

Powering the System

on page 65 for a description of the Power Up

sequence)

BASE RX (Base Station Receive Signal Strength)

BASE RX

-9

Indicates that the Base Station signal strength is -9 dBm

BASE RX

OPT

Indicates that the Display is showing Optical link signal strength

BASE RX

-9

Repeat of the Base Station signal strength

BASE RX

OPT

Repeat that the display is showing Optical link signal strength

This display cycle repeats itself and depending on timing may start with
either OPT of the strength measurement.

CAM RX (Camera Unit Receive Signal Strength)

CAM RX

COPT

Sequence starts with COPT to indicate camera optical signal strength

CAM RX

-9

Indicates that the signal strength from the Camera Unit is -13 dBm

CAM RX

OPT

Indicates that the Display is showing Optical link signal strength

NOTE: the only way to distinguish between BASE RX and CAM RX is to
check the Display Mode LED indicator.

CAM RX

-9

Repeat of the Camera Unit signal strength

CAM RX

OPT

Repeat that the display is showing Optical link signal strength

This manual is related to the following products: