beautypg.com

Grass Valley 3400 CopperHead User Manual

Page 60

background image

54

Connecting the Transceiver System

Connectors into and out of the CopperHead 3400 Base Station

19 & 20

Intercom Connectors #1 & #2

XLR 3 pin or 5 pin Connector depending on configuration. One of three
options will be installed (4-wire intercom, RTS or Clear-Com). See

Understanding Intercom Usage with the CopperHead 3400

on page 66 for

information on using each of the Intercom Options.

22

ST Fiber Connectors (used in place of connector 4)

Two ST Connector receptacles – Used as the Fiber Optic connection typically
when infrastructure wire or with one of the two external power supply
option (MPS or HDX Power Adaptors).

23

12V Terminal Block

Terminal Block – bare wire connector. This can be used in place of the ADAP
power connection in installations that have 12V power distributed as part of
their infrastructure. Do not use this at the same time as the ADAP power
connection.

24

Molex Power Connectors (used in place of 4 and only if so configured with
ST Fiber Connectors)

5 Conductor Molex Connector – Used to provide power to the Hybrid Fiber
Optic Cable. Typically installed with infrastructure wiring with cable leading
from Molex connector to a panel mounted OpticalCON receptacle.

Diagram # Description

This manual is related to the following products: