Configuring the ethernet port parameters, Upgrading a system software image file – H3C Technologies H3C WX3000E Series Wireless Switches User Manual
Page 61

53
1.
Connect the Ethernet port GigabitEthernet 1/0/1 of the switch to the PC by using a crossover
Ethernet cable, and configure IP addresses for the Ethernet port of the switch and the PC, which
must be on the same network segment so that the switch and the PC can communicate with each
other. For example, set the IP address of the VLAN interface to 192.168.0.1 and that of the PC to
192.168.0.2.
2.
Run TFTP Server on the PC, and set the path of the system software image file to be downloaded.
CAUTION:
•
The TFTP server software is not provided with the WX3024E. You must make sure that it is available by
yourself.
•
Only the management Ethernet port, GigabitEthernet 1/0/1, can be used for system software image file
upgrade.
Configuring the Ethernet port parameters
Before upgrading a system software image file through the management Ethernet port, configure the port
as follows:
Select 3 from the BootWare main menu to enter the Ethernet submenu and select 5 to enter the Ethernet
port configuration submenu.
============================
|Note: '.' = Clear field. |
| '-' = Go to previous field. |
| Ctrl+D = Quit. |
===============================================================================
Protocol (FTP or TFTP) :tftp
Load File Name :wx3000.bin
:
Target File Name :wx3000.bin
:
Server IP Address :192.168.0.2
Local IP Address :192.168.0.1
Gateway IP Address :0.0.0.0
FTP User Name :
FTP User Password :
NOTE:
When configuring a parameter, enter a new value, or press Enter to accept the default value that follows
a colon. You can type . to clear the current input, - to return to the previous parameter field, and Ctrl+D to
quit from the parameter configuration interface.
Upgrading a system software image file
After configuring the Ethernet port parameters, select 3 from the BootWare main menu to enter the
Ethernet submenu and then select 2. In this example you upgrade the main system software image file.
The following information appears:
Loading..............................................................................
.....................................................................................
.....................................................................................
.....................................................................................
.....................................................................................