beautypg.com

Leds – H3C Technologies H3C WX3000E Series Wireless Switches User Manual

Page 40

background image

32

NOTE:

Before you connect a networking device by using optical fibers, make sure that the fiber connectors work
with the transceiver modules.

Before connecting fiber cables, make sure that the optical power of the receiver end does not exceed the
upper threshold of the receiving optical power of the transceiver module; otherwise, the transceiver

module may be damaged. For the optical power specifications of the receiver end, see the chapter

“Appendix B Transceiver module specifications.”

LEDs

Table 10 LED description

LED Mark Status

Description

Power status LED
(green/yellow/red)

PWR

Steady green

The system is going through the power on self
test (POST) or downloading software.

Flashing green (1 Hz)

The system is working properly.

Steady red

The system failed to pass the POST or has
detected a serious fault.

Steady yellow (1 Hz)

At least one port has failed the POST or
detected a minor fault.

Off

No AC input is present.

PoE/PoE+ status LED
(green/yellow)

Mode

Steady green

The PoE/PoE+ is operational.

Flashing green (3 Hz)

PoE/PoE+ supply is not available because the
maximum output power of the port is exceeded

or the remaining power is insufficient.

Steady yellow

The ports cannot provide PoE/PoE+ supply due
to an over-temperature, over-voltage, or

under-voltage protection shutdown of the

PoE/PoE+ system.

Flashing yellow (3 Hz)

At least one port failed to pass the POST; if the
PoE sub-board is in position, it may be caused
by a UART communication failure or some other

self test failure.

Off

No PoE/PoE+ supply.

RPS status LED
(yellow/green)

RPS

Steady green

Both AC and DC inputs are normal.

Steady yellow

The AC input is abnormal or no AC input is
present, while the DC input is normal.

Off

No DC input is present.