43

Figure 39 Set up a web configuration environment

NOTE:

By default, ports GE 1/0/1 and GE 1/0/2 on the access controller engine of the WX3024E are
aggregated, and ports GE 1/0/29 and GE 1/0/30 on the switching engine are aggregated. All the

aggregate ports belong to VLAN 1 and can communicate with each other.

The switch has default web login information when shipped. You can use the default information to log
in to the web interface: username admin, password admin, IP address of VLAN-interface 1 of the main

control board 192.168.0.100/24.

2.

Specify an IP address for the PC, for example, 192.168.0.200/24, and make sure that the PC
and the WX3024E can reach each other.

3.

Open the browser, type the IP address 192.168.0.100 in the address bar and press Enter.
The login page of the web interface (see

Figure 40

) appears.

4.

Enter the username and password admin, and the verification code, select the language (English
or Chinese), and click Login.

Figure 40 Web login page

NOTE:

The web configuration interface supports the browsers of Microsoft Internet Explorer 6.0 SP2 and higher,
Mozilla Firefox 3.0 and higher, Google Chrome 2.0.174.0 and higher.

Upgrading the software

1.

Select Device > Device Maintenance from the navigation tree to enter the page as shown in

Figure

41

.

This manual is related to the following products: