CAUTION:

The length of a configuration file name must not exceed 64 characters (including the drive identifier and
the string terminator). For example, if the drive identifier is flash: /, the maximum length of a file name
is [ 64 – 1 – 5 ] = 58 characters.

If the length of a file name exceeds 58 characters, operations on that file will fail, so keep a file name
within 16 characters.

The length of file name that can be displayed in BootWare is limited. If a file name is shorter than 30
characters, all the characters of the file name can be displayed; if a file name has or exceeds 30
characters, only the first 26 characters of the file name can be displayed, followed by a tilde (~) and a

serial number. This serial number identifies the position in sequence of the file. For example, if file A, file

B, and file C have a file name longer than 30 characters, the name of file A will appear as the first 26
characters plus ~001, that of file B will appear as the first 26 characters plus ~002, and that of file C will

appear as the first 26 characters plus ~003.

Approaches for software maintenance

You can maintain the switch in one of the following ways:

Upgrade a system software image file through the web interface.

Upgrade the BootWare and a system software image file by using the XMODEM protocol through
a serial port.

Upgrade the BootWare and a system software image file by using the TFTP/FTP protocol via an

Ethernet port through the BootWare menu or at the CLI.

NOTE:

The BootWare image file is upgraded together with the Comware system software image file. When you
upgrade the Comware system software image file to the latest version, the BootWare file is automatically

upgraded to the latest version.

Before upgrading the software, check the current version of BootWare and that of the system software
image file to make sure that the correct file is used for the upgrade. For the association between the

system software image file version and the BootWare version, see the

Release Notes.

Upgrading a system software image file through the

web interface

Setting up a web configuration environment

To set up a web configuration environment:

1.

Connect Ethernet port GE1/0/1 on the WX3024E to the PC with an Ethernet cable.