Configuring an atm subinterface – H3C Technologies H3C SR8800 User Manual
Page 14
6
Step Command
Remarks
3.
Set the clock mode.
clock { master | slave }
Optional.
Slave by default.
4.
Set the framing format.
frame-format { sdh | sonet }
Optional.
SDH STM-1/STM-4 by default.
5.
Enable payload scrambling.
scramble
Optional.
Enabled by default.
6.
Enable loopback.
loopback { cell | local | remote }
Optional.
Disabled by default.
7.
Configure the MTU.
mtu mtu-number
Optional.
1500 bytes by default.
8.
Set the signal degrade (SD)
threshold and the signal fail
(SF) threshold.
threshold { sd | sf } value
Optional.
By default, the SD threshold is
10e-6, and the SF threshold is
10e-3.
Configuring an ATM subinterface
Configuring an ATM subinterface
To configure an ATM subinterface:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Create an ATM subinterface
and enter its view.
interface atm
interface-number.subnumber
[ p2mp | p2p ]
By default, the connection type of
an ATM subinterface is
point-to-multipoint (P2MP).
3.
Set the MTU for the ATM
subinterface.
mtu mtu-number
Optional.
1500 bytes by default.
4.
Shut down the ATM
subinterface.
shutdown
Optional.
By default, ATM subinterfaces are
up.
CAUTION:
The keywords p2mp and p2p are available with the interface atm
interface-number.subnumber only
when you are creating an ATM subinterface. If you are entering an existing ATM subinterface, the two
keywords are not available.
- H3C SR6600-X H3C SR6600 H3C MSR 5600 H3C MSR 50 H3C MSR 3600 H3C MSR 30 H3C MSR 2600 H3C MSR 20-2X[40] H3C MSR 20-1X H3C MSR 930 H3C MSR 900 H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module