Watson-Marlow MM440 User Manual
Page 65

Issue 10/06
3 Functions
MICROMASTER 440 Operating Instructions
6SE6400-5AW00-0BP0
65
P0809[0] = 0
P0809[1] = 2
P0809[2] = 1
2. CDS 3. CDS
P0700
P0701
P0702
P0703
P0704
..
..
.
P2253
P2254
P2264
..
..
.
..
..
.
..
..
.
[0]
[1]
[2]
1. CDS
1. CDS
3. CDS
Start copy
Fig. 3-9
Copying from CDS
The command data sets are changed-over using the BICO parameter P0810 and
P0811, whereby the active command data set is displayed in parameter r0050
(refer to Fig. 3-10). Changeover is possible both in the "Read" as well as in the
"Run" states.
t
0
1
2
3
(0:0)
BI: CDS b0 loc/rem
P0810
(0:0)
BI: CDS bit 1
P0811
t
0
1
2
3
CO/BO: Act CtrlWd2
r0055
r0055
CO/BO: Act CtrlWd1
r0054
r0054
.15
.15
.15
.15
r0050
CDS active
Selection of CDS
Switch-over time
aprox. 4 ms
Switch-over time
aprox. 4 ms
Fig. 3-10
Changing-over CDS