Watson-Marlow MM440 User Manual
Page 269

Issue 10/06
5 MICROMASTER 440 specifications
MICROMASTER 440 Operating Instructions
6SE6400-5AW00-0BP0
269
Input voltage range
3 AC 380 V – 480 V. ± 10 %
(with built in Class A Filter)
Order No.
6SE6440-
2AD22-
2BA1
2AD23-
0BA1
2AD24-
0BA1
2AD25-
5CA1
2AD27-
5CA1
2AD31-
1CA1
2AD31-
5DA1
[kW]
2.2 3.0 4.0 5.5
7.5 11.0 15.0
Output Rating (CT)
[hp]
3.0 4.0 5.0 7.5 10.0
15.0
20.0
Output Power
[kVA]
4.5 5.9 7.8 10.1 14.0 19.8 24.4
CT-Input Current 1)
[A]
7.5 10.0 12.8 15.6 22.0 23.1 33.8
CT Output Current
[A]
5.9 7.7 10.2 13.2 18.4 26.0 32.0
VT Input Current 1)
[A]
–
–
– 17.3 23.1 33.8 37.0
VT-Output Current
[A]
–
–
– 20.2 29.0 39.0 45.2
Fuse [A]
16 16 20 20 32 35 50
Recommended 3NA
3805 3805 3807 3807 3812 3814 3820
for UL specified
3NE
*
*
*
*
*
*
1817-0
[mm
2
]
1.5 1.5 2.5 2.5 4.0 6.0 10.0
Input Cable Min.
[awg]
16 16 14 14 12 10 8
[mm
2
]
6.0 6.0 6.0 10.0 10.0 10.0 35.0
Input Cable Max.
[awg]
10
10
10 8 8 8 2
[mm
2
]
1.0 1.0 1.0 2.5 4.0 6.0 10.0
Output Cable Min.
[awg]
18 18 18 14 12 10 8
[mm
2
]
6.0 6.0 6.0 10.0 10.0 10.0 35.0
Output Cable Max.
[awg]
10
10
10 8 8 8 2
[kg]
3.4 3.4 3.4 5.7 5.7 5.7 17.0
Weight
[lbs]
7.5 7.5 7.5 12.5 12.5 12.5 37.0
Order No.
6SE6440-
2AD31-
8DA1
2AD32-
2DA1
2AD33-
0EA1
2AD33-
7EA1
2AD34-
5FA1
2AD35-
5FA1
2AD37-
5FA1
[kW]
18.5 22.0 30.0 37.0 45.0 55.0 75.0
Output Rating (CT)
[hp]
25.0 30.0 40.0 50.0 60.0 75.0 100.0
Output Power
[kVA]
29.0 34.3 47.3 57.2 68.6 83.8 110.5
CT-Input Current 1)
[A]
37.0 43.0 59.0 72.0 87.0 104.0
139.0
CT Output Current
[A]
38.0 45.0 62.0 75.0 90.0 110.0
145.0
VT Input Current 1)
[A]
43.0 59.0 72.0 87.0 104.0
139.0
169.0
VT-Output Current
[A]
45.0 62.0 75.0 90.0 110.0
145.0
178.0
Fuse [A]
63 80 100 125 160 200 250
Recommended 3NA
3822 3824 3830 3832 3836 3140 3144
for UL specified
3NE
1818-0 1820-0
1021-0
1022-0
1224-0
1225-0
1227-0
[mm
2
] 10.0 16.0 25.0 25.0 35.0 70.0 95.0
Input Cable Min.
[awg]
8 6 3 3 2 2/0
3/0
[mm
2
] 35.0 35.0 35.0 35.0 150.0
150.0
150.0
Input Cable Max.
[awg]
2 2 2 2
300
300
300
[mm
2
] 10.0 16.0 25.0 25.0 50.0 70.0 95.0
Output Cable Min.
[awg]
8 6 3 3 1/0
2/0
3/0
[mm
2
] 35.0 35.0 35.0 35.0 150.0
150.0
150.0
Output Cable Max.
[awg]
2 2 2 2
300
300
300
[kg]
17.0 17.0 22.0 22.0 75.0 75.0 75.0
Weight
[lbs]
37.0 37.0 48.0 48.0 165.0
165.0
165.0
1) Secondary conditions: Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
k
= 2 % referred to the rated drive converter power and a rated line supply voltage
of 400 V without line commutating reactor.
* UL listed fuses such as Class NON from Bussmann are required for use in America