5 MICROMASTER 440 specifications
MICROMASTER 440 Operating Instructions
6SE6400-5AW00-0BP0
267
Input voltage range
1 AC 200 V – 240 V. ± 10 %
(Unfiltered)
Order No.
6SE6440- 2UC11
-2AA1
2UC12
-5AA1
2UC13
-7AA1
2UC15
-5AA1
2UC17
-5AA1
2UC21
-1BA1
2UC21
-5BA1
2UC22
-2BA1
2UC23
-0CA1
[kW]
0.12 0.25 0.37 0.55
0.75 1.1 1.5 2.2 3.0
Output Rating (CT)
[hp]
0.16
0.33 0.5 0.75 1.0 1.5 2.0 3.0 4.0
Output Power
[kVA]
0.4 0.7 1.0 1.3 1.7 2.4 3.2 4.6 6.0
CT Input Current 1)
[A]
1.8 3.2 4.6 6.2 8.2 11.0
14.4
20.2
35.5
CT Output Current
[A]
0.9 1.7 2.3 3.0 3.9 5.5 7.4 10.4
13.6
Fuse [A]
10 10 10 16 16 20 20 32 40
Recommended 3NA
3803 3803 3803 3805 3805 3807 3807 3812 3817
for UL specified
* * * * * * * * *
[mm
2
]
1.0 1.0 1.0 1.5 1.5 2.5 2.5 4.0 6.0
Input Cable Min.
[awg]
18 18 18 16 16 14 14 12 10
[mm
2
]
2.5 2.5 2.5 2.5 2.5 6.0 6.0 6.0 10.0
Input Cable Max.
[awg]
14 14 14 14 14 10 10 10 8
[mm
2
]
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5
Output Cable Min.
[awg]
18 18 18 18 18 18 18 18 16
[mm
2
]
2.5 2.5 2.5 2.5 2.5 6.0 6.0 6.0 10.0
Output Cable Max.
[awg]
14 14 14 14 14 10 10 10 8
[kg]
1.3 1.3 1.3 1.3 1.3 3.3 3.3 3.3 5.5
Weight
[lbs]
2.9 2.9 2.9 2.9 2.9 7.3 7.3 7.3 12.1
Input voltage range
3 AC 200 V – 240 V. ± 10 %
(with built in Class A Filter)
Order No.
6SE6440- 2AC23-
0CA1
2AC24-
0CA1
2AC25-
5CA1
[kW]
3.0 4.0 5.5
Output Rating (CT)
[hp]
4.0 5.0 7.5
Output Power
[kVA]
6.0 7.7 9.6
CT Input Current 1)
[A]
15.6 19.7 26.5
CT-Output Current
[A]
13.6 17.5 22.0
VT Input Current 1)
[A]
- 28.3 34.2
VT-Output Current
[A]
- 22.0 28.0
Fuse [A]
25 32 35
Recommended 3NA
3810 3812 3814
for UL specified
* * *
[mm
2
]
2.5 4.0 4.0
Input Cable Min.
[awg]
14 12 12
[mm
2
] 10.0 10.0 10.0
Input Cable Max.
[awg]
8 8 8
[mm
2
]
1.5 4.0 4.0
Output Cable Min.
[awg]
16 12 12
[mm
2
] 10.0 10.0 10.0
Output Cable Max.
[awg]
8 8 8
[kg]
5.7 5.7 5.7
Weight
[lbs]
12.5 12.5 12.5
1) Secondary conditions: Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
k
= 2 % referred to the rated drive converter power and a rated line supply voltage
of 240 V without line commutating reactor.
* UL listed fuses such as Class NON from Bussmann are required for use in America