Channel Rate

Sets the bit rate to BERT for each selected channel. If “

Ν

x64K” is selected,

the ones density requirements of the T1 network line must be ensured. If

Ν

x56K” is selected, ones density for the selected DS0 channel is maintained.

Values: Nx56K, Nx64K
Default: Nx64K

BERT Pattern

Specifies the pattern to be transmitted during a test for the selected port.

Values: Marks, QRSS, 511, 2047, 2

15

, Spaces

Default: QRSS

NOTICE:

The 2

15

pattern is the ITU (European) version, not the ANSI version.

Test Duration

Specifies the length of time for which the test should run for the selected port.

Values: 15 min, 30 min, 1 hour, 24 hours, Continuous
Default: Continuous

You can also view the following read-only parameters from this screen:

Pattern Sync

Displays the state of pattern sync during a test. If no test is in progress, “No
Test” is displayed. If a test is active, but the receiver is not in pattern sync,
“No Sync” is displayed. If the receiver is in pattern sync, “In Sync” is
displayed.

Elapsed Time

Displays the time elapsed since a timed test began or, if completed, the total
test time.

Bit Errors

Displays the total number of bit errors detected since the test began or since
error statistics were cleared.

Errored Seconds

Displays the number of asynchronous errored seconds that have been detected
since the test began or since error statistics were last cleared.

%EFS

Displays the percentage of time that the test ran error-free. This ratio is
derived from the number of error-free seconds divided by the number of
seconds accumulated in Elapsed Time.

Loop Table on Network Interface Test Details Screen

The types of tests available for you to choose from depend on the currently
selected interface. For the Network interface, the Loop table provided near the
bottom of the Test Details screen lets you specify the type of Loop test to be
performed.

Values: No Test (Loop Down), payload loopback (PLB), line loopback

(LLB), maintenance loopback (MLB), Far PLB, Far LLB

Default: No Test (Loop Down)