Serial maintenance menu, Serial maintenance menu -10 – Verilink FrameStart FSM (34-00299.E) Product Manual User Manual

Page 128

background image

5-10

F r a m e S t a r t F S M

Sync

Display-only field shows the state of pattern sync during a BERT. If no
BERT is in progress, “No Test” is displayed. If a BERT is active, but the
receiver is not in pattern sync, “No Sync” is displayed. If the receiver is in
pattern sync, “In Sync” is displayed.

Elapsed

Display-only field shows the amount of time (in seconds) that has elapsed
since a BERT began or, if completed, the total test time.

Bit Errors

Display-only field shows the number of bit errors detected since the BERT
began or since error statistics were last cleared.

ES

Display-only field shows the number of asynchronous errored seconds that
have been detected since the BERT began or since error statistics were last
cleared. This parameter includes bit error seconds and sync loss seconds.

% EFS

Display-only field shows what percent of the total test time ran error free.
This ratio is derived from the number of error free seconds divided by the
number of seconds accumulated in Elapsed Time.

Cmd

Lets you control basic aspects of the BERT performed, including the injection
of errors during test.

Values: Stop, Reset, Error Inject, Start
Default: Stop

Serial Maintenance Menu

The following paragraphs describe the user-selectable and display-only
parameters of the SERIAL interface maintenance menu.

Loop

Lets you specify the type of loop test (if any) performed on the selected serial
interface.

Values: No Test, Port, V.54, Far.V.54
Default: No Test

Setting

Lets you specify the direction towards which the BERT pattern is sent.

Values: Net, DTE
Default: Net

Pattern

Lets you specify the pattern to be transmitted during a BERT for the selected
port.

Values: QRSS, 511, 2047, 2^15, Spaces, Marks
Default: QRSS

NOTICE:

The 2^15 pattern is the ITU (European) version, not the ANSI version.