beautypg.com

Verilink FrameStart FSM (34-00299.E) Product Manual User Manual

Page 115

background image

V T 1 0 0 I n t e r f a c e

4-41

Pattern Sync

Displays the state of pattern sync during a test. If no test is in progress, “No
Test” is displayed. If a test is active, but the receiver is not in pattern sync,
“No Sync” is displayed. If the receiver is in pattern sync, “In Sync” is
displayed.

Elapsed Time

Displays the time elapsed since a timed test began or, if completed, the total
test time.

Bit Errors

Displays the total number of bit errors detected since the test began or since
error statistics were cleared.

Errored Seconds

Displays the number of asynchronous errored seconds that have been detected
since the test began or since error statistics were last cleared.

%EFS

Displays the percentage of time that the test ran error-free. This ratio is
derived from the number of error-free seconds divided by the number of
seconds accumulated in Elapsed Time

Loop Table on the Network Interface Test Details Screen

The Loop table lets you specify the type of Loop test to be performed.

Values: No Test (Loop Down), line loopback (LLB), maintenance

loopback (MLB), Far PLB, Far LLB

Default: No Test (Loop Down)

Figure 4.31

Serial Interface Test Details Screen

BERT Table on the Serial Interface Test Details Screen

The BERT table lets you set the test parameters listed below.

Setting

Displays the bandwidth on which you wish to perform the BERT. The
available values for this parameter depend on which interface is selected.

Values: Net, DTE
Default: Net