beautypg.com

Verilink FrameStart FSM (34-00299.E) Product Manual User Manual

Page 62

background image

3-38

F r a m e S t a r t F S M

CIR Alarm

Reports if the Tx over CIR threshold has been exceeded.

Bits Over Be Threshold

Sets the Tx over the excess burst alarm threshold. This threshold is the
number of bits per second in excess of CIR + Be during a 15-minute interval.
Setting this field to “0” (zero) disables the alarm.

Bits Over Be Alarm

Reports if the Tx over Be threshold has been exceeded.

Congestion Threshold

Sets the Rx Congestion alarm threshold. This threshold is the number of
frames received with BECN/FECN. Setting this field to “0” (zero) disables
the alarm.

Congestion Alarm

Reports if the Rx Congestion threshold has been exceeded.

BECN with CIR

Reports if Backward Explicit Congestion Notification (BECN) has been
received within CIR.

UAS Threshold

Sets the Unavailable Seconds (UAS) alarm threshold. This threshold is the
number of seconds passed that the DLCI is unavailable. Setting this field to
“0” (zero) disables the alarm.

UAS Alarm

Reports if the UAS threshold has been exceeded.

The DLCI Details screen provides the user-activated buttons defined below.

DLCI Statistics Screen

Clicking the “DLCI Statistics” button on the Endpoint DLCI Details screen
will display the following screen:

Button

Function

Submit

Sets and activates newly defined DLCI parameters.

Clear Alarms

Clears all DLCI alarms.

DLCI Statistics

Displays a table of the statistics for this DLCI.

DLCI Table

Displays a table of all DLCIs on a specific frame relay service, with
their state and alarm conditions.

Refresh

Refreshes data on the current page.