Serial configuration menu, Serial configuration menu -14, Notice – Verilink FrameStart FSM (34-00299.E) Product Manual User Manual
Page 132
5-14
F r a m e S t a r t F S M
Serial – Timing is derived from the Serial port recovered clock.
Zero Suppression
Determines whether ones density insertion is activated after 15 zeros. This
parameter is ignored if the Coding parameter is set to “B8ZS”.
Values: Disable, Enable
Default: Disable
PRM
Lets you establish which performance messaging standard will be employed
to initiate Performance Report Message (PRM) functions. Setting this field to
“Enable” instructs the unit to use ANSI T1.403, which sends a PRM once
every second. Setting this field to “Disable” instructs the unit to use AT&T
TR54016, which provides performance reporting on request only.
Values: Disable, Enable
Default: Disable
Serial Configuration Menu
The SERIAL INTERFACE lets you view and make changes to the unit’s
serial interface configurations.
Figure 5.13
Serial Configuration Menu Tree
Use the SERIAL CONFIG to set the configuration parameters defined in the
following paragraphs.
Type
This parameter selects the type of interface (based on its electrical signal
characteristics) used by the equipment connected to the Serial port.
Values: V.35, RS-232, EIA-530
Default: V.35
NOTICE:
V.35 requires the use of an optional cable. Refer to "Optional
Equipment" for ordering information.
V.35
RS-232
EIA-530
Type
Mode
DSR
DCD
CTS
RTS
RTS Delay
Tx Clock
DCE
DTE
True
False
Int
True
False
Int
True
False
In*
Normal
True
Normal
Long
Int
Ext
Nx56
Nx64
(N = 1–32)
Channel
Rate
Rate
Inv Clock
Bundling
Start
Channel
No. of
Channels
V.54
LL
DTR Ctrl
Nx64K
Nx56K
Cont
Alt
1–24
1–24
Dis
En
Dis
En
Dis
En
Dis
En
Serial
Configuration