8
Enter an adjustment for each missing line.
•
Head
- Select the color of the missing line. In the previous example, a missing
line appeared in the black pattern.
•
Page
- Choose whether the missing line is on the first or second test page for
the selected color. In the previous example, the missing line occurred on page
one of the two-page black pattern.
•
Row
- Enter the row number of the missing line. In the previous example, the
missing line occurred in row 50.
•
Column
- Enter the column number of the missing line. In the previous
example, the missing line occurred in column 9.
Choose
Add to List
to add the missing line to the adjustment list. Repeat this
process for all missing lines.
9
If necessary, you can delete items from the adjustment list by selecting the item and
choosing
Remove from List
.
10
When you are finished entering adjustments, choose
Print Confirmation Pattern
.
The pattern will be reprinted, but with your adjustments applied. Examine the
pattern to ensure the missing lines you entered now appear correctly.
11
Choose
Close
when you are finished entering missing nozzle adjustments.
Related Topics:
- Cleaning Printheads on page 74
Calibrating Top of Form
After loading reflective mark media, you may need to calibrate the printer.
This procedure is required only for reflective mark media. It should be performed each
time a reflective mark media roll is loaded.
If you have already calibrated the printer for your reflective mark media, and you are
replacing a reflective mark media roll with an identical roll, repeating calibration is not
necessary.
1
Temporarily remove the label roll from the printer.
2
Launch the Kiaro! Maintenance Utility.
From the Windows Start Menu, choose
Start > All Programs > QuickLabel
Kiaro! > Kiaro! Maintenance Utility
. A language and printer prompt will open.
Select a display language and the Kiaro! printer you want to connect to. Choose
OK
.
3
Choose the
Adjustments
tab.
4
Choose
Top of Form Calibration
. The Top of Form Calibration window will
open.