Microcom 814M Programming Manual User Manual
Page 70

66
[Range]
[Description]
[Notes]
[Reference]
n = 1, 49
Transmits the status specified by n as follows:
N
Function
1, 49
Transmits paper sensor status and paper end sensor status
This command is valid for serial model and / or USB model only. If printer has serial
and USB interfaces, data is returned to serial and USB interfaces at the same time.
The status types to be transmitted are shown below:
Paper sensor status (n = 1, 49):
Bit
Off/On
Hex
Decimal
Status for ASB
Off 00
0
Paper
near-end
sensor: paper adequate
0, 1
On
03
3
Paper near-end sensor: paper near end
Off
00
0
Paper end sensor: paper adequate
2, 3
On
0c
12
Paper end sensor: paper end
4
Off
00
0
Not used. Fixed to 0.
5,6
Undefined
7
Off
00
0
Not used. Fixed to 0.
DLE EOT
GS w n
[Name]
[Format]
[Range]
[Description]
[Default]
[Reference]
Set bar code width
ASCII
GS
w
n
Hex
1D
77
n
Decimal 29
119
n
2 ≤ n ≤ 6
Set the horizontal size of the bar code.
n specifies the bar code width as follows:
Binary-level Bar Code
n
Module Width (dots) for
Multi-level Bar Code
Thin element width
(dots)
Thick element
width (dots)
2 2
2
5
3 3
3
8
4 4
4
10
5 5
5
13
6 6
6
15
♦ Single-level bar codes are as follows:
UPC-A, UPC-E, JAN13 (EAN13), JAN8 (EAN8), CODE93, CODE128
♦ Binary-level bar codes are as follows:
CODE39, ITF, CODABAR
n = 2
GS k