beautypg.com

Microcom 814M Programming Manual User Manual

Page 70

background image

66

[Range]

[Description]

[Notes]

[Reference]

n = 1, 49

Transmits the status specified by n as follows:

N

Function

1, 49

Transmits paper sensor status and paper end sensor status

ƒ

This command is valid for serial model and / or USB model only. If printer has serial

and USB interfaces, data is returned to serial and USB interfaces at the same time.

ƒ

The status types to be transmitted are shown below:

Paper sensor status (n = 1, 49):

Bit

Off/On

Hex

Decimal

Status for ASB

Off 00

0

Paper

near-end

sensor: paper adequate

0, 1

On

03

3

Paper near-end sensor: paper near end

Off

00

0

Paper end sensor: paper adequate

2, 3

On

0c

12

Paper end sensor: paper end

4

Off

00

0

Not used. Fixed to 0.

5,6

Undefined

7

Off

00

0

Not used. Fixed to 0.

DLE EOT

GS w n

[Name]

[Format]

[Range]

[Description]

[Default]

[Reference]

Set bar code width

ASCII

GS

w

n

Hex

1D

77

n

Decimal 29

119

n

2 ≤ n ≤ 6

Set the horizontal size of the bar code.

n specifies the bar code width as follows:

Binary-level Bar Code

n

Module Width (dots) for

Multi-level Bar Code

Thin element width

(dots)

Thick element

width (dots)

2 2

2

5

3 3

3

8

4 4

4

10

5 5

5

13

6 6

6

15

♦ Single-level bar codes are as follows:

UPC-A, UPC-E, JAN13 (EAN13), JAN8 (EAN8), CODE93, CODE128

♦ Binary-level bar codes are as follows:

CODE39, ITF, CODABAR

n = 2

GS k