Microcom 814M Programming Manual User Manual
Page 32

28
[Notes]
[Default]
[Reference]
Printing area height: dy = [dyL + dyH × 256] × (vertical motion unit)]inches
If this command is input in standard mode, the printer executes only internal flag
operation. This command does not affect printing in standard mode.
If the horizontal or vertical starting position is set outside the printable area, the printer
stops command processing and processes the following data as normal data.
If the printing area width or height is set to 0, the printer stops command processing
and processes the following data as normal data.
This command sets the position where data is buffered to the position specified by
ESC T within the printing area.
If (horizontal starting position + printing area width) exceeds the printable area, the
printing area width is automatically set to (horizontal printable area- horizontal starting
position).
If (vertical starting position + printing area height) exceeds the printable area, the
printing area height is automatically set to (vertical printable area – vertical starting
position).
The horizontal and vertical motion units are specified by GS P. Changing the
horizontal or vertical motion unit does not affect the current printing area.
Use the horizontal motion unit (x) for setting the horizontal starting position and
printing area width, and use the vertical motion unit ( y) for setting the vertical starting
position and printing area height.
When the horizontal starting position, vertical starting position, printing area width,
and printing area height are defined as X, Y, Dx, and Dy respectively, the printing area
is set as shown in the figure below.
Decided by printer configuration
CAN, ESC L, ESC T, GS P