beautypg.com

Using the mobile i/o hardware, Mobile i/o front panel, Figure 7 – Metric Halo 2882 operating guide User Manual

Page 16: Mobile i/o user’s guide

background image

Mobile I/O User’s Guide

8

Using the Mobile I/O Hardware

Mobile I/O Front Panel

The Mobile I/O front panel provides ten-segment metering for the 8 analog
inputs and outputs. The meters are fast PPM peak reading meters with
auto-resetting peak holds.

The front panel also provides Mobile I/O system status at a glance:

• Sample Rate (nominal 44.1, 48, 88.2, or 96)

• The Sample Rate is determined from the currently selected clock source

so it will accurately indicate the current sample rate, even when the clock
source is being provided by an external device.

• Clock source:

Internal indicates that the system is internally clocked

Wordclock indicates that system is being clocked from the wordclock

input

256x WC indicates that the system is being clocked from a 256x clock at

the wordclock input

Digital In indicates that the system is being clocked from the selected

digital input (AES or S/PDIF)

256x WC + Digital In indicates that the system is being clocked from

the ADAT optical input

• Power:

• Indicates that the Mobile I/O is receiving power.

• Phantom power

• Indicates that at least one of the preamps has the phantom power

enabled.

Figure 7: Mobile I/O Front Panel