6-8 WaveView

09-29-00

WavePort User’s Manual

File

New

Sets all parameters to their default startup settings.

Open

Loads a saved configuration.

Save

Saves the existing configuration for later recall.

Save As

Prompts for a file name and saves the current configuration to that file name.

Convert Data Files

Runs the File Converter, which converts any acquired data file to any of the supported data

types.

Data Conversion

Preferences

Opens a dialog box, which lets you set the data file conversion options that WaveView will

apply automatically whenever you acquire data.

Open a WBK16

Calibration File
(WBK16 Only)

Loads a WBK16 sensor calibration table. This command loads saved WBK16 calibration

data.

Note: This selection is not available unless WaveView detects the presence of a WBK16.

Exit

Closes WaveView.
Note: Before WaveView exits, it saves the current configuration in a file named

WAVEVIEW.CFG. The next time you run WaveView, this file is loaded automatically.

Edit

Make All Channels

Active

This command places an “On” in the “On/Off” field of all channels.

Make All Channels

Inactive

This command places an “Off” in the “On/Off” field of all channels. If your channel scan

includes only a few channels, it may be easier to make all of the channels inactive, then
turn on only those few channels that you want.

Go To Row

Opens a dialog box that lets you enter a channel number to be modified. For hardware

configurations that contain a large number of channels, this is a faster method of moving
around than using the scroll bars.

Fill Down

When multiple cells within a column are selected, this command takes the top-most

selected cell and copies its contents to the selected cells below.

Hide Inactive

Channels

Temporarily removes all inactive channels from the channel configuration worksheet. If

there are inactive (“Off”) channels, this results in a smaller spreadsheet showing just the
currently active channels. A status indicator “HIDDEN ROWS” appears above the
spreadsheet when one or more channels are hidden.

Note: When a channel is hidden, its configuration settings cannot be changed. Block

operations and other “All” actions, like the Make All Channels Active menu item, have no
effect on hidden channels.

Show All Channels

Makes all channel rows visible. Can be used to restore the full spreadsheet after a Hide

Inactive Channels action.

Auto Zero Enabled

Channels

This zeros out a DC offset signal on all channels that are “On” and have Auto Zero set to

“Yes.”

Enable Spreadsheet

Reading Column

This causes all channels that are “On” to display an actual reading of the input signal in the

channel reading column. This column is updated with new readings about twice per
second. A status indicator “READINGS” appears above the spreadsheet when the
reading column is enabled.

Disable Spreadsheet

Reading Column

This stops the reading column from being updated.

View

Acquisition

Configuration

Opens the display window to allow selection of the number/speed of the scan and the

triggering method to start the scan.

Module Configuration

Opens the display window that shows the current inventory of expansion modules in the

system and allows the configuration of some expansion module parameters.

Scope

Opens the display window to allow real-time viewing of the acquired data.

Direct to Disk

Opens the display window to allow the writing of acquisition data to disk files.

View File Data