beautypg.com

Gasboy FiPay Payment Network User Manual

Page 11

background image

MDE-4999A FiPay™ Payment Network Installation and Setup Instructions · October 2012

Page 11

Islander Plus/CFN Plus Setup

15

Set the Station to process End of Day (Settlement) with the Host network.

a

Enable end of day processing by selecting the Daily run enabled checkbox.

b

Use the Time to run daily drop down boxes to set the time when the End of day will occur

with the Host network.

Figure 5: Setup PAIS Screen

Daily run checkbox and

Time to run drop down

lists

Set to 120

16

Additional settings that are NOT typically changed are as follows:

a

Timeout: 30 seconds is default. This is the time allowed to contact the Host network.

Must be set to 120.

b

Card may not be reused with: 10 minutes is default. This timer controls when the same

card is used second

time. Set 0 to disable.

c

Pre-authorization amount: 400 is default. This is the Maximum dollar amount allowed

even if the Host network authorizes a greater value.

17

Additional setting must NEVER be changed unless advised to by Gasboy Technical Support.

a

PAIS tasks:

b

App log: App Port:

c

Comm log: Comm port: