beautypg.com

M&c interface, j5, Tx if interfaces, j6, j7, and j8, 5 m&c i – Comtech EF Data XSAT-7080 User Manual

Page 62: If i, J6, j7

background image

XSAT7080 X-Band Transceiver

Revision 0

Redundant Systems

MN/XSAT7080.IOM

5-6

5.2.1.5 M&C I

NTERFACE

, J5

The J5 interface connector (19-pin) provides the communications and control signals between the
RSU-5060 and the customer M&C system.

Table 5-7. M&C Signal Description (Connector J5)

Pin Signal Name

Type

Description

A

RS485 RX+

Pass-thru RS-485 Rx+, From M&C to XSAT A&B

B RS485

RX-

Pass-thru

RS-485

Rx-, From M&C to XSAT A&B

C

RS485 TX+

Pass-thru RS-485 Tx+, To M&C from XSAT A&B

D

RS485 TX-

Pass-thru RS-485 Tx-, To M&C from XSAT A&B

E

B ONLINE CLOSED Output

Shorted to pin K = XSAT B Online

F n.c.

G n.c.

H n.c.

J n.c.

K IND/FLT

COMMON Input

L

A FAULT OPEN

Output

Shorted to pin K = XSAT A Faulted

M

B FAULT OPEN

Output

Shorted to pin K = XSAT B Faulted

N n.c.

P

RED AUTO/MAN

Input

Ground = Manual, Open = Auto

R n.c.

S

A ONLINE CLOSED Output

Shorted to pin K = XSAT A Online

T GROUND

Passive

U GROUND

Passive

V

SWITCH CMD

Input

Momentary short to GND, otherwise OPEN

5.2.1.6 T

X

IF I

NTERFACES

, J6, J7,

AND

J8

The Tx IF input signal is fed from the customer’s equipment to the RSU-5060 at connector J6.
The RSU-5060 contains a power splitter which feeds the IF input signal to both XSAT A and
XSAT B via the J7 and J8 connectors. The IF power at J7 and J8 will nominally be 3dBm less
than the IF input power at J6.

If the RSU 5060 contains the IF transfer switch option, the power splitter is replaced with an IF
transfer switch. This allows the customer to access the offline transceiver.