beautypg.com

System operation, Pin-outs, Chapter 3. system operation – Comtech EF Data XSAT-7080 User Manual

Page 27

background image

3–1

Chapter 3. SYSTEM OPERATION

This section contains instructions for operating the XSAT-7080, X-Band Transceiver.
The Primary customer interface to the XSAT is via the Remote Communications port.

Chapter

4 provides details regarding the protocol and command/response structure used

on this interface. This chapter will define in detail the controllable parameters provided
via the command/response structure.

3.1 P

IN

-

OUTS

3.1.1 C

ONNECTOR

J3: AC

P

OWER

, M

AINS

, 100

TO

125 VAC,

OR

205

TO

240 VAC.

WARNING

To avoid a serious shock hazard, correctly determine the mating
connector type in use and wire it according to the following table:

Early Units

Later Units

Pin Mating Connector Type

KPT06J12-3S

MS3116J12-3S

Mating Connector Type

CA3106E18-22SB

A Line

Ground

B Ground

Neutral

C Neutral

Line