Parameter
Type



Command
(Instruction
Code and
qualifier)

Arguments
for
Command
or
Response
to Query



Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.



Response to
Command
(Slave to Master)



Query
(Instruction
code and
qualifier)




Response to Query
(Slave to Master)

Concise
Utility Status

N/A

10 bytes,
alpha
numerical

Query only.
Used to Query the Utility status of the XSAT
Example: CUS=brrru.ud.d’cr’’lf’
where:

b = baud rate, 1 = 1200, 2 = 2400,

3 = 4800, 4 = 9600, and 5 = 19200

rrr = reference adjust

u.u = Up converter slope adjust

d.d = Down converter slope adjust

N/A CUS?

CUS=x….x (see description for
details of arguments)

Concise
Maintenance
Status

N/A

80 bytes,
numerical

Query only.
Used to Query the Maintenance status of the XSAT
Example: CMS=aaa.abbb.bccc.cddd.deee.e
fff.fggg.ghhh.hiii.ijjj.jkkk.klll.lmmm.m
nnn.nooo.oppp.p’cr’’lf’
where:

aaa.a = 24V Power Supply

bbb.b = 20V Power Supply

ccc.c = 12V Power Supply

ddd.d = 10V Power Supply

eee.e = +5V Power Supply

fff.f = -5V Power Supply

ggg.g = Tx Synthesizer Tuning Voltage

hhh.h = Tx IFLO Tuning Voltage

iii.i = Rx Synthesizer Tuning Voltage

jjj.j = Rx IFLO Tuning Voltage

kkk.k = Reference Tuning Voltage

lll.l = LNA Current in milliamps

mmm.m = Fan Current in milliamps

nnn.n = Up Conv Heat Sink Temperature

ooo.o = RF Output Power in Db

ppp.p = Down Converter Temperature

N/A CMS?

CMS=x….x (see description for
details of arguments)