Specification
MN/XSAT7080.IOM
2–2
Common
Environmental
Conversion
Dual, No Spectral Inversion
Temperature:
Operating
Non-Operating
-40 to +55
°C (-40 to 131°F)
-50 to +75
°C (-58 to 167°F)
Frequency
Step Size
1 and 2.5 MHz automatic
Attitude
15,000 Feet, mean sea level
Frequency
Stability
± 1 x 10
-9
/day
1 x 10
-7
/day
40
° to 55°C 1 x 10
-8
/ Temp
Humidity
0 to 100 %, Relative
Attenuation
Steps
TX
RX
0 to 25 dB, in 0.25 dB steps
0 to 20 dB, in 0.25 dB steps
Prime Power
90 to 260 VAC Standard
47 to 63 Hz Standard
48 VDC Optional
Phase
Noise
100 Hz
1 kHz
10 kHz
100 kHz
-66 dBc/Hz
-76 dBc/Hz
-86 dBc/Hz
-96 dBc/Hz
Dimensions:
5 to 25W
50W
100W
11H x 8W x 11D inches
(28H x 20W x 28D cm)
9.75H x 10W x 23d inch
(25H x 25W x 58D cm)
10.60H x 12.5W x 26D inches
(27H x 32W x 66D cm)
Group
Delay
Linear
Parabolic
Ripple
0.1 ns/MHz
0.02 ns/MHz
2
1 ns/p-p
Weight:
5 to 25W
50W
100W
36 lbs (16 kg)
65 lbs (29 kg)
80 lbs (40 kg)
Monitor & Control
Low Noise Amplifier
Customer defined
Methods
Both RS-485 and RS-232 Serial
Interface Handheld controller, optional
Model:
Commands Set
TX
frequency
Set RX frequency
Set TX attenuation
Set RX attenuation
Report TX output power
Mute TX
Report internal temperature
Report power supply voltages
Set time
Set date
RF
Power
AC Power
5W
165W
10W
220W
25W
275W
50W
450W
100W
825W
Faults Upconverter
functions
Downconverter functions
Upconverter Synthesizers
Downconverter Synthesizers
Internal Reference Oscillator
LNA current fault