beautypg.com

Comtech EF Data XSAT-7080 User Manual

Page 22

background image

XSAT7080 X-Band Transciever

Revision 0

Specification

MN/XSAT7080.IOM

2–2


Common

Environmental

Conversion

Dual, No Spectral Inversion

Temperature:

Operating
Non-Operating


-40 to +55

°C (-40 to 131°F)

-50 to +75

°C (-58 to 167°F)

Frequency
Step Size

1 and 2.5 MHz automatic

Attitude

15,000 Feet, mean sea level

Frequency
Stability

± 1 x 10

-9

/day

1 x 10

-7

/day

40

° to 55°C 1 x 10

-8

/ Temp

Humidity

0 to 100 %, Relative

Attenuation
Steps

TX
RX

0 to 25 dB, in 0.25 dB steps
0 to 20 dB, in 0.25 dB steps

Prime Power

90 to 260 VAC Standard
47 to 63 Hz Standard
48 VDC Optional

Phase
Noise

100 Hz
1 kHz
10 kHz
100 kHz

-66 dBc/Hz
-76 dBc/Hz
-86 dBc/Hz
-96 dBc/Hz

Dimensions:

5 to 25W


50W



100W


11H x 8W x 11D inches
(28H x 20W x 28D cm)

9.75H x 10W x 23d inch
(25H x 25W x 58D cm)

10.60H x 12.5W x 26D inches
(27H x 32W x 66D cm)

Group
Delay

Linear
Parabolic
Ripple

0.1 ns/MHz
0.02 ns/MHz

2

1 ns/p-p

Weight:

5 to 25W
50W
100W


36 lbs (16 kg)
65 lbs (29 kg)
80 lbs (40 kg)

Monitor & Control

Low Noise Amplifier

Customer defined

Methods

Both RS-485 and RS-232 Serial
Interface Handheld controller, optional

Model:

Commands Set

TX

frequency

Set RX frequency
Set TX attenuation
Set RX attenuation
Report TX output power
Mute TX
Report internal temperature
Report power supply voltages
Set time
Set date

RF

Power

AC Power

5W
165W

10W
220W

25W
275W

50W
450W

100W
825W

Faults Upconverter

functions

Downconverter functions
Upconverter Synthesizers
Downconverter Synthesizers
Internal Reference Oscillator
LNA current fault
Overtemperature condition