beautypg.com

Comtech EF Data XSAT-7080 User Manual

Page 54

background image

XSAT7080 X-Band Transceiver

Revision 0

Remote Control

MN/XSAT7080.IOM


4-18




Parameter
Type



Command
(Instruction
Code and
qualifier)

Arguments
for
Command
or
Response
to Query



Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.



Response to
Command
(Slave to Master)



Query
(Instruction
code and
qualifier)




Response to Query
(Slave to Master)

Concise
Configuration
Status

N/A

31 bytes,
alpha
numerical

Query only.
Used to Query the Configuration status of the XSAT
Example: CCS=uuuu.udddd.daa.aabb.bbotamrncfx’cr’’lf’
where:

uuuu.u = Tx frequency

dddd.d = Rx frequency

aa.aa = Tx attenuation

bb.bb = Rx attenuation

o = online status, 0 = OFFLINE, 1 = ONLINE

t = transmitter status, 0 = OFF, 1 = ON

a = amplifier status, 0 = OFF, 1 = ON

m = Tx mute status, 0 = Unmuted, 1 = Muted

r = receiver status, 0 = OFF, 1 = ON

n = Rx mute status, 0 = Unmuted, 1 = Muted

c = cold start, 0 = Disabled, 1 = Enabled

f = auto fault recover, 0 = Disabled, 1 = Enabled

x = external reference present, 0 = NO, 1 = YES

N/A CCS?

CCS=x….x (see description for
details of arguments)

Concise LNA
Status

N/A

4 bytes,
alpha
numerical

Query only.
Used to Query the LNA status of the XSAT
Example: CLS=abbc’cr’’lf’
where:

a = LNA Current 0=OFF, 1=ON

bb = Current window in %

c = LNA Fault Logic 0=OFF, 1=ON

N/A CLS?

CLS=x….x (see description for
details of arguments)