4-22 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005
To review various configuration options, see the discussions following “Summary of
Array Configuration” on page 5-1. Refer also to the configuration options presented in
the SANnet II 200 FC and SATA Array Best Practices Manual.
In dual-controller arrays, SFPs are initially plugged into one of each pair of host and
drive ports. The default port connections are:
■
The upper I/O controller module has SFPs in the FC0, FC2, and FC4 ports.
■
The lower I/O controller module has SFPs in the FC1, FC3, and FC5 ports.
This configuration provides connections to all six host channels as well as to both
drive channels (see Figure 4-17 and Figure 4-18).
Figure 4-17 Default Dual-Controller SANnet II 200 FC Array SFP Placement
Figure 4-18 Default Dual-Controller SANnet II 200 SATA Array SFP Placement
Note –
The SANnet II 200 SATA SE array configuration does not include SFPs. SFPs
must be ordered separately.
In the default single-controller array, SFPs are initially plugged into the following
ports:
■
FC0
■
FC1
■
FC4
■
FC5
Host port FC0
Drive port FC2
Host port FC4
Host port FC1
Drive port FC3
Host port FC5
H/D/RCC
H/D/RCC
Host port FC0
Host port FC1
Drive port FC2
Drive port FC3
Host port FC4
Host port FC5