7-3

setting up a configuration with redundant pathing. Multipathing software makes
multiple paths between the server and the storage system and provides full services on
each path for path failover.

Refer to the appendix for your host and to the SANnet II 200 FC, SATA, and SATA SE
Array Release Notes
for information about which versions of SANpath software are
supported on your platform. Refer to these release notes for information about
additional supported or provided software.

7.1.4

Enabling VERITAS DMP

To enable VERITAS Dynamic Multi-Pathing (DMP) support on VERITAS Volume
Manager in the Solaris operating system, perform the following steps.

Note –

To see instructions for enabling VERITAS DMP on other supported platforms,

refer to your VERITAS user documentation.

1. Configure at least two channels as host channels (channels 1 and 3 by default) and add

additional host IDs, if needed.

2. Connect host cables to the I/O host ports configured in Step 1.

3. Map each LUN to two host channels to provide dual-pathed LUNs.

4. Add the correct string to vxddladm so VxVM can manage the LUNs as a multipathed

JBOD.

5. Reboot the hosts. System reboot is required to implement these changes.

Note –

JBOD arrays require a license from VERITAS to enable any of its advanced

features. Refer to VERITAS Volume Manager Release Notes or contact VERITAS
Software Corporation for licensing terms and information.

# vxddladm addjbod vid=Dot Hill pid=”SANnet II FC”

# vxddladm listjbod

VID

PID

Opcode Page

Code Page Offset SNO

length

==========================================================

======

SEAGATE ALL

PIDs

18

-1

36

12

Dot Hill

SANnet II FC

18

-1

36

12