8-2 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

8.1.1

Cooling Element Sensors

There are two fans in each power supply module. The normal range for fan speed is
4000 to 6000 RPM. Cooling element failure occurs when a fan’s speed drops below
4000 RPM.

Figure 8-1 Cooling Fan Locations

Table 8-1 Cooling Element Sensors for FC, SATA, and SATA SE Arrays

Element
ID

Description

Location

Alarm
Condition

0

Cooling Fan 0 Power Supply 0

< 4000 RPM

1

Cooling Fan 1 Power Supply 0

< 4000 RPM

2

Cooling Fan 2 Power Supply 1

< 4000 RPM

3

Cooling Fan 3 Power Supply 1

< 4000 RPM

FAN 0

FAN 1

FAN 3

PS0

PS1

FAN 2