beautypg.com

2 drive leds, Drive leds – Dot Hill Systems II 200 FC User Manual

Page 131

background image

Chapter 8 Troubleshooting Your Array

8-13

Figure 8-3 Power Supply or Fan Module Flowchart, 2 of 2

8.7.2

Drive LEDs

Before you perform the drive LED troubleshooting procedures, you might want to use
the firmware application to identify a failed drive. Refer to the SANnet II Family RAID
Firmware User’s Guide
for more details.

Is the power

cord connected?

Is the

power supply

module completely

seated and the power

switch turned on?

Yes

Yes

Resolved?

No

End

Yes

Resolved?

No

End

Yes

Is the fan

spinning?

Yes

No

Try a known

good power

supply module

in that slot.

Yes

No

No

End

Reseat the module

and turn on the

switch.

No

Plug it in.

Resolved?

Replace chassis.

Refer to

FRU Installation

Guide for

instructions.

No

Power supply is working

properly (green LED).

Power supply

module LED

amber?

1B

Power supply or fan problem

Yes

--Reseat the FRU that is not operating correctly.

--Swap the questionable FRU with a known-good FRU
from the same array.

Notes

When a power supply fails the fans will continue to
operate because their power is pulled from a power bus
on the midplane.

Prior to replacing a chassis, try the following: